BabyLife BLF-2001

Infant Incubator

Kiemelt előnyök

  • Humidity servo (0-95%)
  • 3 litres destillated and residual water reservoirs
  • Air temperature servo control w/ override (25-39 oC)
  • Glass-like transparent single wall hood, x-ray compatible
  • Hood with front access door
  • Hood with 4 noiseless, easy to open hand ports / windows
  • Hood with 2 iris ports / windows
  • Hood with 6 tube ports
  • Cradle with anti-decubitus mattress, x-ray compatible
  • Space for x-ray casette under the cradle
  • Mechanical one step cradle tilting, up to 12 degree
  • Heavy duty stand with 4 castors (2 lockable)
  • Instrument shelf on the stand
  • Protector and instrument holder rails on each side
  • HEPA 13 air filter
  • State-of-the-art microprocessor controller
  • 5” bi-colour LCD display
  • Waterresistant, foil-covered keypad with lock
  • Test button / Self test / Silence / Reset button
  • Display of heating intensity, date, set and real values
  • 3/24/170 hours trends
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)

Tulajdonságok

The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard those of the 93/42/EEC Directive. The materials used comply with to the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards.
The hood has six fully transparent windows (with iris opening upon request) and a large (upon request two) door(s). An X-ray cassette can be inserted under the cradle or on a cassette holder tray (optional). The cradle with the baby can be placed into an inclined position (even electrically upon request; optional), and the baby can be removed from the incubator safely and quickly together with the cradle.
ln the hood the air streams along the longitudinal axis of the baby's body. When the door is opened, an air curtain develops in the door. The hood of the unit may be single or double walled (optional).
The incubators are equipped with foil-covered keyboards and graphic LCD displays. Settings are easy to understand having the lowest possible number of controls. Set and real-time measured values are constantly shown on the LCD display.
The noise level in the hood is below 45 dBA (40 dBA as option). The opening and closing of windows is absolutely noiseless. The air flow rate is well below the value allowed by the relevant standards.
Oxygen supply in the hood is controlled by a rotameter between 21-40% (optional). An electronic oxygen servo unit provides higher oxygen concentration far more intensity between 21-75% ( opt iona 1). The i ncubators may be ordered a lso with head hood and with warmed humidified oxygen servo control (21-95%) (optional).
ln the incubator, the baby's weight is measured with high accuracy by an electronic scale located under the cradle, the measured value is shown on the graphic display, while data are stored (optional). The height of the lying surface can be made electronically adjustable upon request (optional).

BLF-2001 incubators are micro-computer controlled . When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remete control, as well as the saving and printing of measured values and trends (optional).

The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:

  • temperature of air in the hood
  • humidity of air in the hood
  • baby's skin temperature (optional)
  • oxygen concentration (optional)
  • weight (optional)
  • second body temperature (optional)

The temperature control ranges of the incubator are as follows:

  • in normal mode of operation in the case of 'air control' 27-37°C in the case of skin control 34-36°C.
  • ln 'override' operation in the case of 'air control' 37-39°C, in the case of 'skin control' 36-38°C.

Galéria

Ajánlatkérés

done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Glass-like transparent single wall hood,x-ray compatible done
Double or triple wall hood
Front access door done
Rear access door
4 noiseless, easy to open hand port / window done
2 iris port / window done
Additional hand port instead of iris port
6 tube port done
Additional tube port(s)
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Cradle with foam mattress, x-ray compatible
Cradle with anti-decubitus mattress, x-ray compatible done
Gel mattress
Drawable x-ray casette tray
Space for x-ray casette under the cradle done
Inclination of cradle indicator
Electric cradle tilting (continuous, up to 15o, both direction)
Mechanical cradle tilting (one step, up to 12o, both direction) done
Drawable cradle
Net mattress
Drawable x-ray casette tray with window
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Protector bumpers and instrument holder rails on each side done
Gas cylinder holder on the stand
Cupboard with two drawers on the stand
Instrument shelf on the stand done
Electric height adjustment with foot pedal
Electric height adjustment 900 - 1150 mm
Heavy duty steel stand with 4 castors (2 lockable) done
Painted steel stand with 4 castors (2 lockable)
IV pole with monitor shelf
IV pole
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Visual and audible alarms and backup sensors done
7” colour LCD display
10.4” colour touchscreen monitor
Set / Display of date / time / humidity / temperature, etc. done
Keypad lock done
Display of heating intensity, 3/24/170 hours trend, real and measured values done
Waterresistant, foil-covered keypad with lock done
State-of-the-art microprocessor controller done
Integrated camera
UPS (Uninterruptible Power Supply) from 30 min operation time
HEPA 13 air filter done
5” LCD display done
WIFI connection
LAN connection
RS-232 connector done
Test button / Self test / Silence / Reset button done
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Humidity servo (0-95%) with 3 litres reservoir done
Ultrasonic humidifier with 1 liter reservoir
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Air temperature servo control (25-39 oC) done
Skin temperature servo control (34-38 oC)
Peripherial skin temperature sensor
Peripherial rectal temperature sensor
Reusable / Disposable skin temperature sensor
Reusable / Disposable rectal temperature sensor
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Oxygen dosage through flowmeter (21-40%)
Reusable / Disposable SpO2 sensor
Built-in pulseoximeter with colour LCD
Built-in weighing scale with drawable cradle (0-10 kg)
Oxygen sensor
Flowmeter with heated humidifier
Oxygen servo in hood and head-hood (21-75/95%)
Oxygen servo in head-hood (21-95%)
Oxygen servo in hood (21-75%)
Oxygen concentration meter (0-100%)
SpO2 extension cord
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Fixing head frame
Head-hood
Neonate protecting eyemask (disposable, 10 pcs)
Reusable cover for hood
Reusable cover for incubator
done Tartalmazza a csomag | remove Nem tartalmazza | Választható Standard verzió
Language English done
Language CN/DE/ES/FR/HU/RU Upon request